4 Receiving
No.
5
EMC noise filter
A: No built-in EMC filter
6
Protection design
B: IP20/UL Open Type
W: IP55/UL Type 12 Heatsink External Mounting
7
Environmental specification
M: Resistant to dust/humidity

Rated Output Current

Table 4.2
to
Table 4.3
give the rated output current values.
Note:
• These output current values apply to drives that operate at standard specifications.
• Derate the output current for applications that require:
–Higher carrier frequencies
–Ambient temperature beyond nameplate ratings
–Drives installed side-by-side.
• Use C6-01 [Normal / Heavy Duty Selection] to select Normal Duty rating (ND) or Heavy Duty rating (HD).
Model
2004
2006
2008
2010
2012
2018
2021
2030
2042
2056
2070
2082
2110
2138
2169
2211
2257
2313
2360
2415
10
Table 4.2 Three-Phase AC 200 V Class
Heavy Duty Rating (HD)
Parameter C6-01 = 0
Maximum Applicable Motor
Output
kW (HP)
0.55 (3/4)
0.75 (1)
1.1 (1 1/2)
1.5 (2)
2.2 (3)
3 (4)
3.7 (5)
5.5 (7 1/2)
7.5 (10)
11 (15)
15 (20)
18.5 (25)
22 (30)
30 (40)
37 (50)
45 (60)
55 (75)
75 (100)
90 (125)
110 (150)
Description
Maximum Applicable Motor
Rated Output Current
A
3.5
5
6.9
8
11
14
17.5
25
33
47
60
75
88
115
145
180
215
283
346
415
YASKAWA TOEPC71061737B GA800 Drive Installation & Primary Operation
Normal Duty Rating (ND)
Parameter C6-01 = 1 (Default)
Rated Output Current
Output
kW (HP)
0.75 (1)
1.1 (1 1/2)
1.5 (2)
2.2 (3)
3 (4)
3.7 (5)
5.5 (7 1/2)
7.5 (10)
11 (15)
15 (20)
18.5 (25)
22 (30)
30 (40)
37 (50)
45 (60)
55 (75)
75 (100)
90 (125)
110 (150)
110 (150)
A
4.2
6
8
9.6
12.2
17.5
21
30
42
56
70
82
110
138
169
211
257
313
360
415