Wiring the Main Circuit Terminal Block Using Procedure B

Notes on Wiring the Main Circuit Terminal Block
Note:
• After you connect the wire to the terminal, do not twist or move it too much.
• Be sure to use only wires with the correct size, stripped wire length, and tightening torque as specified by Yaskawa.
• Use tools that fit the shape of the screw head to tighten and loosen the terminal block screws.
• Make sure that there are no loose stranded wires or frayed wires after wiring is complete.
Main Circuit Terminal Block Wiring Procedure
Remove the terminal cover before wiring the main circuit terminal block.
1.
Remove the screws on the terminal block cover and pull the terminal block cover away from the drive. Pull the
wiring cover away from the drive to remove the wiring cover after removing the terminal block cover.
A - Terminal block cover
2.
Remove the terminal block nut.
A - Nut
3.
Wire the closed-loop crimp terminal to the main circuit terminal block.
YASKAWA TOEPC71061737B GA800 Drive Installation & Primary Operation
B - Wiring cover
Figure 7.11 Remove the Wiring Cover
Figure 7.12 Remove the Terminal Block Nut