3-5 PUMP REPLACEMENT

Remove the Front Cover and Right I/S Cover.
1
Turn on the Sub Power SW while pressing the Left, Right
2
and Down keys to enter the Service Mode.
Select [I/S MENU] > [I/S CONTROL] > [CAP] > [OPEN],
3
and press the [ENTER] key. The Capping Unit moves
down and allows you to move the Head Carriage by hand.
Move the Head Carriage slowly leftwards to the position
4
where it is not above the Capping Unit.