4-8 CAP HEIGHT ADJUSTMENT (Referential Time : 5min.)
Cap Height Adjustment is to adjust the height of the cap.
This adjustment is required when the cap unit is removed or replaced.
Without this adjustment, the Cap Evacuation* may not be performed properly.
* Cap Evacuation is an operation of ink evacuation with the Heads uncapped. This removes
the ink accumulated on the Cap surfaces.
For this adjustment, the Head height can be either High or Low. When it is adjusted with one of the Head
heights, the setting for the other height is also changed automatically.
Open the Front Cover and remove the Right Inner Plate.
1
Right Inner Plate has a small hook on its right
bottom and it is inserted to the lower cover.
Be cautious when removing it.
Make sure to unload the media when it is set on the
2
machine.
Then, turn on the Sub Power SW while pressing [ ] [ ]
and [
] keys to enter the Service Mode.
Select [I/S MENU] > [CAP ADJUST] > [ADJUST POS.]
3
menu in the Service Menu.
Front Cover
Right Inner Plate
MENU
SERVICE MENU
SERVICE MENU
I/S MENU
I/S MENU
CAP ADJUST
CAP ADJUST
ADJUST POS.
4-42
+