Print Key; Operating Data Printout - York YCWL0056SE Installation Operation & Maintenance

Water-cooled liquid chillers
Table of Contents

Advertisement

FORM 201.26-NM1
ISSUE DATE: 1/19/2018

Print Key

The PRINT key allows the operator to obtain a printout
of real-time system operating data or a history print-
out of system data at the "instant of the fault" on the
last six faults which occurred on the unit. An optional
printer is required for the printout.

Operating Data Printout

Pressing the PRINT key and then OPER DATA key
allows the operator to obtain a printout of current sys-
tem operating parameters. When the OPER DATA key
is pressed, a snapshot will be taken of system operat-
ing conditions and panel programming selections. This
data will be temporarily stored in memory and trans-
mission of this data will begin to the printer. A sample
Operating Data printout is shown below. (Note: Not all
values are printed for all models. Not all data applies
to a YCWL chiller.)
YORK INTERNATIONAL CORPORATION
MILLENNIUM LIQUID CHILLER
UNIT STATUS
2:04PM 01 JAN 10
SYS 1
SYS 2
OPTIONS
CHILLED LIQUID
AMBIENT CONTROL
LOCAL/REMOTE MODE
CONTROL MODE
LEAD/LAG CONTROL
FAN CONTROL
CURRENT FEEDBACK
POWER FAILURE RESTART
SOFT START
EXPANSION VALVE
REMOTE TEMP RESET
PROGRAM VALUES
DSCH PRESS CUTOUT
SUCT PRESS CUTOUT
SUCT PRESS CUT COOLING
SUCT PRESS CUT HEATING
LOW AMBIENT CUTOUT
LEAVING LIQUID CUTOUT
ANTI RECYCLE TIME
FAN CONTROL ON PRESS
FAN DIFF OFF PRESS
NUMBER OF COMPRESSORS
NUMBER OF FANS PER SYSTEM
UNIT TRIP VOLTS
REFRIGERANT TYPE
DEFROST INIT TEMP
DEFROST INITIATION TIME
DEFROST TERMINATION TIME
BIVALENT HEAT DELAY TIME
REMOTE UNIT ID PROGRAMMED
YORK HYDRO KIT PUMPS
PUMP TOTAL RUN HOURS
JOHNSON CONTROLS
NO COOLING LOAD
COMPRESSORS RUNNING 2
WATER
STANDARD
REMOTE
LEAVING LIQUID
AUTOMATIC
AMB & DSCH PRESS
NONE
AUTOMATIC
ENABLED
THERMOSTATIC
4 TO 20 MA
570 PSIG
80 PSIG
42 PSIG
31 PSIG
25.0 DEGF
25.0 DEGF
600 SECS
425 PSIG
125 PSIG
6
4
3.0
R-22
41.0 DEGF
60MIN
3MIN
30 MIN
2
1 (410a)
XXXXX (410a)
SECTION 7 – UNIT CONTROLS
UNIT DATA
RETURN LIQUID TEMP
LEAVING LIQUID TEMP
DISCHARGE AIR TEMP
COOLING RANGE
HEATING RANGE
122.0 +/- 2.0 DEGF
SYS 1 SETPOINT
SYS 2 SETPOINT
REMOTE SETPOINT
AMBIENT AIR TEMP
LEAD SYSTEM
EVAPORATOR PUMP
EVAPORATOR HEATER
ACTIVE REMOTE CONTROL
LAST DEFROST SYS X DURATION
TIME TO SYS X DEFROST
BIVALENT DELAY REMAINING
UNIT XXX.X AMPS
SOFTWARE VERSION
SYSTEM 1 DATA
COMP STATUS
RUN TIME
0- 0- 0- 0 D-H-M-S
TIME YYYYYYY
0- 0- 0- 0 D-H-M-S
LAST STATE
SUCTION PRESSURE
DISCHARGE PRESSURE
SUCTION TEMPERATURE
SAT SUCTION TEMP
SUCTION SUPERHEAT
COOLER INLET REFRIG
DEFROST TEMPERATURE
LIQUID LINE SOLENOID
MODE SOLENOID
HOT GAS BYPASS VALVE
CONDENSER FAN STAGE
EEV OUTPUT
SYSTEM
XXX.X AMPS X.X VOLTS
SYSTEM 2 DATA
COMP STATUS
RUN TIME
TIME YYYYYYY
LAST STATE
SUCTION PRESSURE
DISCHARGE PRESSURE
SUCTION TEMPERATURE
SAT SUCTION TEMP
SUCTION SUPERHEAT
COOLER INLET REFRIG
DEFROST TEMPERATURE
LIQUID LINE SOLENOID
MODE SOLENOID
CONDENSER FAN STAGE
EEV OUTPUT
SYSTEM
XXX.X AMPS
DAILY SCHEDULE
S M T W T F S
*=HOLIDAY
SUN START=00:00AM
STOP=00:00AM
MON START=00:00AM
STOP=00:00AM
TUE START=00:00AM
STOP=00:00AM
WED START=00:00AM
STOP=00:00AM
THU START=00:00AM
STOP=00:00AM
FRI START=00:00AM
STOP=00:00AM
SAT START=00:00AM
STOP=00:00AM
HOL START=00:00AM
STOP=00:00AM
58.2 DEGF
53.0 DEGF
55.3 DEGF
42.0 +/- 2.0 DEGF
70 +/- 3 PSIG
70 +/- 3 PSIG
44.0 DEGF
74.8 DEGF
SYS 2
ON
OFF
NONE
XXXS
XX MIN
XX MIN
X.X VOLTS
C.M02.13.00
1=OFF 2=OFF 3=OFF
YYYYYYY
105 PSIG
315 PSIG
46.0 DEGF
34.0 DEGF
12.0 DEGF
31.6 DEGF
52.8 DEGF
OFF
OFF
OFF
OFF
0.0 %
1=ON, 2=OFF, 3=ON
0-0-1-46 D-H-M-S
0-0-0-0 D-H-M-S
YYYYYYY
110 PSIG
320 PSIG
49.3 DEGF
36.0 DEGF
13.3 DEGF
31.6 DEGF
52.8 DEGF
ON
ON
3
63.2%
X.X VOLTS
127
7