14. Parameter

14.1. Common to predictive maintenance functions

(*1 Attributes in the table, R: Read only, W: Write only, R/W: Read/write)
Parameter
Pause method of
warning occurrence
Predictive/preventive
maintenance function
enable/disable
switching
Predictive
maintenance function
enable/disable status
Version management
of
predictive/preventive
maintenance function
Parameter 160
Parameter
Number of
name
elements
PMSTPWAY
Integer 1
PMENA
Integer 1
MSPPMENB
Integer 1
PMVER
Character
string
Details explanation
Specify the pause method of warning
occurrence or warning signal output of
the predictive/preventive maintenance
function.
Specify the behavior of the
predictive/preventive maintenance
function when warning occurrence or
warning signal output is paused.
1: Pause until maintenance (occurs
only once when power is input).
(Warning occurs or a warning signal is
output once immediately after power
input and pause continues after reset.)
2: Pause until maintenance (stops as
well when power is input)
Specify enable/disable of the
predictive/preventive maintenance
function.
This parameter is used when a
customer who uses the "MELFA
Smart Plus Card Pack" disables the
predictive/preventive maintenance
function in order to continue using the
maintenance forecast.
You can check whether or not the
predictive maintenance function is
enabled. (Read only)
1: Enable
0: Disable
Manages the version of the
predictive/preventive maintenance
function.
Factory
Attribute
setting
*1)
1
R/W
0
R/W
R
R

Hide quick links: