13.3.5. Detection level

M_PMWngDrv:Detection level (reduction gear abnormality detection)
[Function]
Returns the detection level (reduction gear abnormality detection) of the specified axis.
[Syntax]
Example) <Numeric variable> = M_PMWngDrv<Axis number>
[Term]
<Numeric variable> Specify the numeric variable to assign.
<Axis number> Specify the joint axis to retrieve the detection level (reduction gear abnormality
detection) from. (1 to 6)
When omitted, 1 is used.
[Example]
M1 = M_PMWngDrv(1)
[Comments]
(1) Returns the detection level (reduction gear abnormality detection) of the joint axis specified in <Axis
number> for the robot (mechanism 1).
(2) This variable is read-only.
'The detection level (reduction gear abnormality detection) of Axis J1 is set
in M1.