Perform Engine Maintenance -
Deutz Models
Engine specifications require that this procedure
be performed every 500 hours or semi-annually,
whichever comes first.
Required maintenance procedures and additional
engine information is available in the Deutz 1011F
Operation Manual (Deutz part number 0297 9683)
or the Deutz 2011 Operation Manual (Deutz part
number 0297 9929).
Deutz 1011F Operation Manual
Genie part number
Deutz 2011 Operation Manual
Genie part number
Part No. 72863
Section 3 • Scheduled Maintenance Procedures
C-4
Replace the Hydraulic Tank
Breather Cap - Models with
Optional Hydraulic Oil
Genie specifications require that this procedure be
performed every 500 hours or semi-annually,
whichever comes first.
The hydraulic tank is a vented-type tank. The
breather cap has an internal air filter that can
become clogged or, over time, can deteriorate. If
the breather cap is faulty or improperly installed,
impurities can enter the hydraulic system which
may cause component damage. Extremely dirty
52883
conditions may require that the cap be inspected
more often.
84794
1 Remove and discard the hydraulic tank breather
cap.
2 Install and new cap onto the tank.
C-5
Perform Engine Maintenance -
Ford Models
Engine specifications require that this procedure
be performed every 800 hours or semi-annually,
whichever comes first.
Required maintenance procedures and additional
engine information is available in the
Ford LRG425 Operator Handbook
(Ford part number FPP 194-302).
Ford LRG 425 Operator Handbook
Genie part number
GS-3390 • GS-4390 • GS-5390
CHECKLIST C PROCEDURES
84792
3 - 31