Software Configuration (After Serial Number Gs9003-41522) - Genie GS-3390 Service Manual

Hide thumbs Also See for GS-3390:
Table of Contents

Advertisement

Section 4 • Repair Procedures
GROUND CONTROLS
5-3
Software Configuration
(after serial number GS9003-41522)
How to Configure the Software
The Electronic Control Module (ECM) contains
programming for all configurations of the GS-90.
Models after serial number GS9003-41522 can be
adjusted to a different configuration using the
buttons at the ground controls.
ANSI and CSA models:
1 Pull out the red Emergency Stop button to the
on position at the platform controls.
2 Push in the red Emergency Stop button to the
off position at the ground controls.
3 Turn the key switch to ground control.
4 Press and hold both the blue platform up and
yellow platform down buttons. Pull out the red
Emergency Stop button to the on position at the
ground controls.
Result:
is showing in the diagnostic
TUNE SPEEDS
display window.
a
a
diagnostic display
b
blue platform up button
c
lift function enable button
d
yellow platform down button
4 - 70
Machine Option Definitions
Descent Delay: This option halts descent at
approximately 12 feet / 3.6 m. All controls must
be released for 4 to 6 seconds before descent is
re-enabled. Required for Europe.
Lift/Drive Cut Out: Lift and drive functions are
disabled when the down limit switch is activated
and the machine is on a slope exceeding the
rating on the serial plate. Activated for all
machines.
Motion Alarm: The motion alarm will sound
when activating a function.
Motion Beacons: The flashing beacons operate
only when activating a function.
Overload: This cuts out all functions when the
platform overload pressure switch is tripped. The
red Emergency Stop button must be cycled
before any function can be resumed. Required
for Europe.
Sim Operation: When enabled, this allows
some machine functions to be activated
simultaneously. Required to be disabled for
European models.
Beacons: When installed on the machine, the
b
flashing beacons operate continuously when the
key switch is to ground or platform controls and
c
both red Emergency Stop buttons are in the on
position.
d
5 Use the yellow platform down arrow to scroll to
select options.
Result:
diagnostic display window. The ECM is now in
programming mode.
GS-3390 • GS-4390 • GS-5390
is showing in the
SELECT OPTIONS
July 2007
REV D
Part No. 72863

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gs-4390Gs-5390

Table of Contents