REP 7.23 Tray 3 and Tray 4 Elevator Motor (W/TAG 151)

Parts List on
PL
7.21.
Removal
Switch off the electricity to the machine,
customer supply while performing tasks that do not need electricity. Electricity can
cause death or injury. Moving parts can cause injury.
Take care during this procedure. Sharp edges may be present that can cause injury.
1.
Pull out tray 3 and tray 4.
2.
Remove the rear cover from the HCF,
3.
Disconnect PJ395 or PJ397 elevator motor harness from the
4.
Disconnect the harness from the low paper sensor on the elevator motor.
Repairs/Adjustments
REP 7.23
WARNING
GP
14. Disconnect the power cord from the
WARNING
PL 7.25 Item
1.
HCF control
PWB,
5.
Remove the tray 3 or tray 4 elevator motor,
P/J13
Figure 1 Elevator motor removal
Replacement
The replacement is the reverse of the removal procedure.
May 2013
4-104
Figure
1.
2
Disconnect P/J14
P/J14
3
4
Remove
Remove the tray 4
the screw
elevator motor
4
Remove the tray 3 elevator motor
3
Remove the screw
2
Disconnect P/J13
1
Disconnect the sensor harness
Xerox® WorkCentre® 5790 Family
1
Disconnect
the sensor
harness