Rep 4.7 Main Drive Belts, Drive Gears And Idlers (65-90 Ppm) - Xerox WorkCentre 5790 Series Service Manual

Table of Contents

Advertisement

1
Ensure that the tabs are located in the bracket.
Figure 4 Main drive PWB location
2.
Ensure that the support bracket on the main drive module is located correctly with the
drive shafts and the collar,
Figure
5. Then secure the support bracket.
Position the collar and 3 shafts correctly in the bracket
Figure 5 Main drive module support bracket
3.
Before installing the main drive module turn the drive gears by hand to position the drive
belts correctly on the drive gears.
Xerox® WorkCentre® 5790 Family

REP 4.7 Main Drive Belts, Drive Gears and Idlers (65-90 ppm)

Parts List on
PL 4.12
Removal
Switch off the electricity to the machine,
customer supply while performing tasks that do not need electricity. Electricity can
cause death or injury. Moving parts can cause injury.
Take care during this procedure. Sharp edges may be present that can cause injury.
1.
Remove the main drive module,
2.
Remove the drives support bracket,
2
Remove the support
bracket.
Figure 1 Drives support bracket
3.
Refer to
Figure
2, to remove the following:
Main drive belt 2
Fuser drive gear
Output paper path drive gear
Intermediate drive gear
Idler
May 2013
4-49
WARNING
GP
14. Disconnect the power cord from the
WARNING
REP
4.5.
Figure
1.
1
Remove six screws.
Repairs/Adjustments
REP 4.6, REP 4.7