Take care not break the inverter assembly bracket.
3.
Carefully unlatch the inverter assembly bracket from the inverter assembly,
2
Use a screwdriver to
unlatch the clip on the
inverter assembly
bracket from the tie bar
Figure 2 Inverter assembly bracket
Repairs/Adjustments
REP 10.11
CAUTION
Figure
1
Remove 2 nuts
Inverter assembly
bracket
4.
Remove the inverter path solenoid link,
NOTE: When the link arm has been removed, a new link arm must be installed,
2.
Item
1.
May 2013
4-216
Figure
3.
Figure 3 Inverter path solenoid link