STARTER via PROFINET IO (example)
Figure 2-6
Procedure for activating online mode with PROFINET
1. Setting the IP address in Windows XP
2. Settings in the STARTER commissioning tool
3. Select online operation in the STARTER commissioning tool.
Setting the IP address in Windows XP
On the desktop, right-click on "Network environment" -> Properties -> double-click on
Network card and choose -> Properties -> Internet Protocol (TCP/IP) -> Properties -> Enter
the freely-selectable addresses.
Figure 2-7
Commissioning Manual
Commissioning Manual, (IH1), 01/2011, 6SL3097-4AF00-0BP1
STARTER via PROFINET (example)
The programming device (PG/PC) is assigned a fixed, free IP address.
Internet Protocol (TCP/IP) properties
Commissioning
2.2 STARTER commissioning tool
61