Control Unit 310-2Dp In Operation - Siemens SINAMICS S120 Commissioning Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Diagnostics
3.1 Diagnostics via LEDs
3.1.1.8

Control Unit 310-2DP in operation

Table 3- 11
Description of the LEDs during operation of the CU310-2 DP
LED
Color
RDY
-
(READY)
Green
Red
Red / green Flashing light
Orange
Green /
orange
or
red /
orange
COM
-
Green
Red
MOD
-
OUT > 5 V
-
Orange
1) Make sure that the connected encoder is designed for a 24 V supply. Connecting a 5 V encoder to a 24 V supply can
result in destruction of the encoder electronics.
168
State
Description / cause
Off
Electronic power supply is missing or outside
permissible tolerance range.
Continuous light
The unit is ready for operation.
Cyclic DRIVE-CLiQ communication is in progress.
Flashing light
Commissioning / reset
0.5 Hz
Flashing light 2
Writing to the memory card.
Hz
Flashing light
General errors
2 Hz
The Control Unit is ready for operation, but there
0.5 Hz
are no software licenses.
Flashing light
The firmware of the DRIVE-CLiQ components is
0.5 Hz
being updated.
Flashing light
DRIVE-CLiQ component firmware update
2 Hz
completed. Waiting for POWER ON of the
corresponding components.
Detection of the component via LED is activated
Flashing light
(p0124[0]).
2 Hz
Note:
Both options depend on the LED state when
activating via p0124[0] = 1.
Off
Cyclic communication is not (yet) running.
Note: The PROFIdrive is ready for communication
when the Control Unit is ready for operation (see
LED: RDY).
Continuous light
Cyclic communication is taking place.
Flashing light
Cyclic communication is not fully established yet.
0.5 Hz
Possible causes:
- The controller is not transmitting any setpoints.
- In isochronous mode, the controller is not sending
a GC (Global Control) or is sending a defective GC
Flashing light
The PROFIBUS master is sending a faulty
0.5 Hz
parameter assignment or the configuration file is
corrupted.
Flashing light
Cyclic bus communication has been interrupted or
2 Hz
could not be established.
Off
-
Off
-
Continuous light
The voltage of the electronic power supply for the
measuring system is 24 V.
1)
Commissioning Manual, (IH1), 01/2011, 6SL3097-4AF00-0BP1
Remedy
Check the power
supply
-
-
-
Check parameter
assignment /
configuration
Install the missing
licenses.
-
Switch on the
component.
-
-
-
-
Modify the
configuration between
the master / controller
and Control Unit.
Rectify the bus
communication fault.
-
-