6 DriveProgramming Commands
Accel
Command
Sets the inverter acceleration time.
This command is a =(Assign) command whose
left-hand side is set to the acceleration time
variable ACCEL.
Unit: 10 ms
Decel
Command
Sets the inverter deceleration time.
This command is a =(Assign) command whose
left-hand side is set to the deceleration time
variable DECEL.
Unit: 10 ms
Precautions for Correct Use
• The acceleration time variable ACCEL and the deceleration time variable DECEL are
enabled only when you set the Acceleration/Deceleration Time Input Type (AC-01) to 04
(DriveProgramming).
• When the DriveProgramming program is stopped, the data of the acceleration time variable
ACCEL and deceleration time variable DECEL before the program stop is retained. When
the program execution is started again, the process begins with the retained data.
6 - 62
Description
Flowchart method
=
ACCEL :
<value>
Description
Flowchart method
=
DECEL :
<value>
Value: any variable or constant
Format
Text language method
ACCEL : = <value>
Value: any variable or constant
Format
Text language method
DECEL : = <value>
DriveProgramming User's Manual (I622-E1)
Argument
Argument