var = func
Command
Assigns the status of the output variable to
<variable>.
For details, refer to 5-7 Output Variables on page 5-21.
 Example
In the above example, 1 is assigned to U(00) when ZS (0 Hz detection signal) is ON, and 0 is assigned
to U(00) when ZS (0 Hz detection signal) is OFF.
Block number
1
Assigns the status of ZS to U(00).
2
Jumps to the block 1: loop_ unconditionally.
DriveProgramming User's Manual (I622-E1)
Description
Flowchart method
=
<variable> :
<function>
Flowchart
6 DriveProgramming Commands
Variable: any variable
Function: any bit of the output variable
Format
Text language method
<variable> : = <function>
Operation
Argument
Text
6 - 41