Inverter Parameters Affected By Setting Order - Omron RX2 Series User Manual

Driveprogramming, cx-drive
Hide thumbs Also See for RX2 Series:
Table of Contents

Advertisement

7 Precautions for Use of Parameters for DriveProgramming
7-1
Inverter Parameters Affected by
Setting Order
In some cases, the setting range of the parameters are restricted by the setting data of other parameters.
The following are the representative examples.
For details, refer to the High-function General-purpose Inverter 3G3RX2 Series User's Manual (I620).
Parameter
No.
Hb104
Async.Motor Base frequency setting, 1st-
motor
Hb105
Async.Motor Maximum frequency setting, 1st-
motor
Hd104
Sync.Base frequency setting, 1st-motor
Hd105
Sync.Maximum frequency setting, 1st-motor
Hb204
Async.Motor Base frequency setting, 2nd-
motor
Hb205
Async.Motor Maximum frequency setting,
2nd-motor
Hd204
Sync.Base frequency setting, 2nd-motor
Hd205
Sync.Maximum frequency setting, 2nd-motor
AA104
Sub speed setting, 1st-motor
AA204
Sub speed setting, 2nd-motor
Ab110
Multispeed-0 setting, 1st-motor
Ab210
Multispeed-0 setting, 2nd-motor
Ab-11 to
Multispeed-1 setting to 15 setting
Ab-25
bA-60
Dynamic brake usage rate
bA102
Upper Frequency limit, 1st-motor
bA103
Lower Frequency limit, 1st-motor
bA202
Upper frequency limit, 2nd motor
7 - 2
Description
Data
10.00 to Maximum Frequency [Hb105](Hz)
Base Frequency [Hb104] to 590.00 (Hz)
10.00 to Maximum Frequency [Hd105](Hz)
Base Frequency [Hd104] to 590.00 (Hz)
10.00 to Maximum Frequency [Hb205](Hz)
Base Frequency [Hb204] to 590.00 (Hz)
10.00 to Maximum Frequency [Hd205](Hz)
Base Frequency [Hd204] to 590.00 (Hz)
0.00/Minimum Frequency [Hb130][Hd130] to Maxi-
mum Frequency [Hb105][Hd105](Hz)
0.00/Minimum Frequency [Hb230][Hd230] to Maxi-
mum Frequency [Hb205][Hd205](Hz)
0.00/Minimum Frequency [Hb130][Hd130] to Maxi-
mum Frequency [Hb105][Hd105](Hz)
0.00/Minimum Frequency [Hb230][Hd230] to Maxi-
mum Frequency [Hb205][Hd205](Hz)
0.00/Minimum Frequency [Hb130][Hd130] to Maxi-
mum Frequency [Hb105][Hd105](Hz)
0.0 to 10.0 × (Dynamic brake usage rate resistance
[bA-63]/Minimum resistance)
Upper Frequency limit, 1st-motor [bA102] ≤
Async.Motor Maximum frequency setting, 1st-motor
[Hb105]
Upper Frequency limit, 1st-motor [bA102] ≤
Sync.Maximum frequency setting,
1st-motor[Hd105]
Lower Frequency limit, 1st-motor [bA103] ≤
Async.Motor Maximum frequency setting, 1st-motor
[Hb105]
Lower Frequency limit, 1st-motor [bA103] ≤
Sync.Maximum frequency setting,
1st-motor[Hd105]
Upper frequency limit, 2nd motor [bA202] ≤
Async.Motor Maximum frequency setting, 2nd-
motor [Hb205]
Upper frequency limit, 2nd motor [bA202] ≤
Sync.Maximum frequency setting, 2nd-motor
[Hd205]
DriveProgramming User's Manual (I622-E1)
2
(%)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3g3rx2 series

Table of Contents