Roland Double Sheet Detector R1000 Series Manual page 82

Inductive principles – microcontroller based
Table of Contents

Advertisement

Start-up
Static Teach-In 2-sheet:
Program Parameter: 9
Teach-In 2-sheet
feed 2-sheet
then press ENTER
Fig. 50: Teach-In procedure for 2-sheet
The double sheet must be moved into mid-position between the sensors. With the ENTER key the
Teach-In for 2-sheet
Dynamic Teach-In 2-sheet:
Program Parameter: 9
Teach-In 2-sheet
drive 2-sheet through
then press ENTER
Fig. 51: Teach-In procedure for 2-sheet
The double sheet must be moved through the sensor gap in mid position. With the ENTER key the
measurement value will be stored.
The dynamical
After the
Teach-In for 2-sheet
Program Parameter: 9
Teach-In 2-sheet
finished
push ENTER
Fig. 52: Teach-In finished
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
82
Double Sheet Detector-series I20
The position of the sheet for Teach-In for 2-sheet must match with the
Note
position in measurement operation. Otherwise the measurement result can
become faulty.
will be performed.
Teach-In for 2-sheet
is suitable especially for magnetical conveyor belt applications.
the following message is shown: