Roland Double Sheet Detector R1000 Series Manual page 23

Inductive principles – microcontroller based
Table of Contents

Advertisement

Manual
Double Sheet Detector-series I20
B0069991 / Rev. 1.7
System description
„Output level 0-1-2-warning"
Sets the output logic (0-sheet, 1-sheet, 2-sheet, warning) to 0V or +24V.
"Automat. prog. select"
Selects the method of program selection. If the program is switched frequently, "no" should be
selected, otherwise the memory would be loaded with frequent writing cycles and its lifetime would
decrease (1.000.000 writing cycles).
"IN / OUT PLC voltage"
Monitores the external PLC voltage. If "monitoring" is set and the PLC voltage is not connected, an
error condition would be detected.
"External Adjust"
Determines whether an external Teach-In / zero adjust is to be possible. If "yes" is set, the PLC can
trigger the procedure via the inputs "Teach-In 0-, 1-sheet". Default setting is "no".
The external adjust may only be performed under supervision of an operator.
"Internal analog zero"
Only for service personnel.
"Internal analog gain"
Only for service personnel.
"Diagnostic"
Diagnostics of the factors determined during the Teach-In. No default setting.
"Compensation factor"
Projected function.
"System info"
Displays the versions of Software and Hardware as well as the bus information.
Identification of the control unit. These information needs to be at hand for telephone support.