6.3.12 Reset error
With the "Reset error" function uncritical faults can be redressed.
Critical errors like "cable rupture" can only be redressed with the control unit keys.
Before the "Reset error" is initiated, all inputs must be LOW for 10 ms.
1
Switch input IN9 "Reset error" to HIGH.
2
Within 10ms all outputs are switched to LOW.
3
If the fault can be reset, the output OUT0 will be set to HIGH.
Switch the input IN9 "Reset error" to LOW.
4
Within 10ms all outputs are switched to HIGH.
5
6.4

Internal control (Demo mode)

In this operating mode the system continuously executes measurements and activates
OUT0 ... OUT4.
In general, this operating mode is suitable for demonstration purposes only.
Prerequisites:
Supply voltage applied
System parameter "Measurement mode" set to "demo"
Teach-In has been executed