Roland Double Sheet Detector R1000 Series Manual page 61

Inductive principles – microcontroller based
Table of Contents

Advertisement

B0069991 / Rev. 1.7
6.3.5
Clear 2-sheet / Clear 0-1-2-sheet, warning outputs
In case of double sheet detection clearing is possible only if the unit is adjusted to "Hold 2-Sheet".
IN 0-4, 6-9
Check whether the output OUT0 "Enable" has been switched to HIGH (ready for operation),
1
otherwise a fault condition is existing.
All inputs must be LOW for 10ms before "Clear 2-Sheet" is activated.
2
Switch input IN5 "Clear 2-Sheet" to HIGH.
3
Within 10ms the outputs OUT1...OUT4 are set to HIGH.
4
After a minimum time of 10ms switch the input IN5 "Clear 2-Sheet" to LOW.
5
Within 10ms the unit can be operated via the inputs.
6
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector-series I20
OUT 0
Enable
Clear 2-sheet /
IN 5
Clear outputs
0-sheet
OUT 3
OUT 2
1-sheet
2-sheet
OUT 1
Warning
OUT 4
1
min.10ms
2
Manual
max.10ms
4
min.10ms
3
5
Communication with the PLC
max.10ms
6
61