RF200 system planning
4.2 Field data of transponders and readers
4.2.2

Minimum clearances

Minimum distance from transponder to transponder
The specified distances refer to a metal-free environment. For a metallic environment, the
specified minimum distances must be multiplied by a factor of 1.5.
Table 4- 14
MDS D100
MDS D117
MDS D124
MDS D126
MDS D127
MDS D139
MDS D160
MDS D165
MDS D200
MDS D261
MDS D324
MDS D339
MDS D400
MDS D421
MDS D422
MDS D423
MDS D424
MDS D425
MDS D426
MDS D428
MDS D460
All values are in mm, relative to the operating distance (S
40
Minimum clearances for transponders
RF210R
between transponder edge and transponder edge
RF220R
-
-
≥ 15
-
≥ 25
≥ 40
-
≥ 50
≥ 15
-
-
-
≥ 20
≥ 25
-
-
-
-
-
-
≥ 25
≥ 40
-
-
-
-
≥ 10
-
≥ 15
≥ 20
-
-
≥ 25
≥ 40
≥ 20
≥ 25
-
≥ 50
≥ 25
≥ 25
≥ 20
≥ 25
System Manual, 09/2013, J31069-D0227-U001-A8-7618
RF240R
-
-
≥ 90
≥ 100
-
-
≥ 70
-
-
-
≥ 90
-
-
-
≥ 50
≥ 80
≥ 90
≥ 75
≥ 90
≥ 75
≥ 70
) between reader and transponder, and
a
RF260R
≥ 240
-
≥ 180
≥ 180
-
≥ 200
≥ 150
≥ 240
≥ 240
≥ 200
≥ 180
≥ 200
≥ 240
-
-
≥ 160
≥ 180
-
≥ 180
≥ 150
≥ 150
SIMATIC RF200