Transponder
7.15 MDS D422
Mounting information for screws
You can screw the transponder into a pre-drilled threaded hole using the screw-in aid.
Mounting information for adhesion
● Drill installation hole
● The adhesive surfaces must be dry, free from dust, oil, stripping agents and other
impurities
● Apply adhesive according to the manufacturer's processing instructions
● Press in MDS D422 using your fingers; with antenna side to the outside (see Fig.)
● Remove residues of adhesive
● Allow to cure according to the manufacturer's instructions
● Flush-mounting of MDS D422 in metal with tools
7.15.4
Technical specifications
Product type designation
Memory size
Memory configuration
•
•
•
Storage technology
Memory organization
Protocol
Data retention (at +40 °C)
MTBF (at +40 °C)
Data transmission rate
Reading and writing
Bulk detection/multitag capability
Read cycles
Write cycles
(at +40 °C, typical)
Read/write distance (S
216
Serial number
Configuration memory
Application memory
)
g
MDS D422
2048 bytes
8 bytes (fixed code)
•
40 bytes
•
2000 bytes
•
FRAM
FRAM 2048 bytes / gross
2000 bytes net
Only for the RF300:
When using the OPT area, 16 bytes of it must be
subtracted in 8 byte blocks
ISO 15693
10 years
2 x 10
h
6
approx. 2 ms/byte
Yes
unlimited
>10
10
See section Field data (Page 35)
System Manual, 09/2013, J31069-D0227-U001-A8-7618
6GT2600-4AF00
SIMATIC RF200