Transponder
7.6 MDS D139
7.6.3
Metal-free area
Direct mounting of the MDS D139 on metal is not allowed. A distance of ≥ 30 mm is
recommended. This can be achieved using spacers, see Auto-Hotspot.
Figure 7-11
Note
If the minimum guide values (h) are not observed, a reduction of the field data results. It is
possible to mount the MDS with metal screws (M5). This has no tangible impact on the
range. It is recommended that a test is performed in critical applications.
7.6.4
Technical specifications
Table 7- 15
Memory size
Memory configuration
•
•
•
Storage technology
Memory organization
Data retention
MTBF
Read cycles
176
Metal-free area for MDS D139
Technical data for MDS D139
Serial number
Configuration memory
Application memory
128 bytes
8 bytes (fixed code)
•
8 bytes
•
112 bytes
•
EEPROM
See MOBY D System Manual,
Chapter 5.1, "Mobile Data Storage Units, Introduction",
section "Memory Allocation"
10 years
2 x 10
hours
6
Unlimited
System Manual, 09/2013, J31069-D0227-U001-A8-7618