Mds D339; Characteristics; Ordering Data - Siemens SIMATIC Ident System Manual

Hide thumbs Also See for SIMATIC Ident:
Table of Contents

Advertisement

7.12

MDS D339

7.12.1

Characteristics

MDS D339
7.12.2

Ordering data

Table 7- 22
Ordering data for MDS D339
Transponder
MDS D339
Table 7- 23
Ordering data for MDS D339 accessories
Accessories
Spacers
Quick change holder
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Characteristics
Field of application
Memory
Read/write range
Mounting on metal
ISO standard
High degree of protection
Material
Order number
6GT2600-3AA10
Order number
6GT2690-0AA00
6GT2690-0AH00
Applications in production automation with high
temperature demands (up to +220 °C)
Typical application areas:
Paintshops and their preparatory treatments
Primer coat, electrolytic dip area, cataphoresis
with the associated drying furnaces
Top coat area with drying furnaces
Washing areas at temperatures > 85 °C
Other applications with higher temperatures
1024 bytes of EEPROM/gross
992 bytes of user memory
See Chapter Field data (Page 35).
With spacer;
recommended distance from metal ≥ 30 mm
ISO 15693
IP68, IPx9K
Plastic PPS; silicone-free
Transponder
7.12 MDS D339