RF200 system planning
4.3 Installation guidelines
Transponder
MDS D460
1)
The values in the table describe the reduction of the field data. All values are percentages relative to
4.3.4.6

RF290R

The RF290R reader is operated with the external antennas ANT D5, D6 and D10. The
antennas can be flush-mounted in metal. Please allow for a possible reduction in the field
data values.
Figure 4-13
To avoid any influence on the field data, the distance a should be ≥ 150 or 200 mm.
62
without metal
1)
on metal, distance 25 mm
flush-mounted in metal
Mounting the transponder on or in metal is only possible with the appropriate spacer or if there is
adequate clearance to the metal.
non metal (100% means no influence).
Metal-free space for ANT D5
Reader
Reader on
without direct
metal
metal
(metal plate)
influence
100
95
90
85
not intended use
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Reader flush-
mounted in metal
(all round 20 mm)
90
80
SIMATIC RF200