Transponder
7.3 MDS D124
Ambient temperature
Weight
1)
2)
3)
4)
7.3.5

Use of the MDS D124 in hazardous area

The mobile data memory MDS D124, device group II, category 1G or 1D may be installed
and operated in zones 0, 1 and 2 or in the zones 20, 21 and 22.
The requirements of the directive 94/9/EC are met by the use of the following standards:
EN 60079-0:2009, EN 60079-11:2007, EN 61241-11:2006 and EN 60079-26:2007
When used in hazardous areas, the MDS D124 must not be operated with field strengths > 5
A / m to avoid impermissible heating. This is not the case with readers from the SIMATIC RF
range (MOBY D, RF200 and RF300).
Identification
II 1 G Ex ia IIC T3 to T6 Ga
or
II 1 D Ex ia IIIC T80 °C to T180 °C Da
TÜV 12 ATEX 084413 X
The temperature class or the maximum surface temperature depends on the maximum
ambient temperature. The relationship between temperature class (gas) or maximum surface
temperature (dust) can be found in the following table.
166
During operation
Transport and
storage
2 hours, 2 m, +20 °C
steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75 °C
The values for shock and vibration are maximum values and must not be applied continuously.
Note that processing is not possible at temperatures of +140 °C or higher.
-25 ... +100 ℃
+120 ... +140 ℃
+200 ℃
4)
+220 ℃
4)
-40 ... +100 ℃
approx. 50 g
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Permanent
20% reduction in the limit
distance
Tested up to 5000 hours
or 3000 cycles
Tested up to 2000 hours
or 1500 cycles