7.4.3

Technical specifications

Table 7- 10
Memory size
Memory configuration
Storage technology
Memory organization
Protocol
Data retention (at +40 °C)
Data transmission rate
Bulk detection/multitag capability
Read cycles
Write cycles at +40 °C, typical
Read/write distance (S
Distance from metal
Power supply
Degree of protection to EN 60529
Shock, tested in accordance with IEC 68-2-27
Vibration, tested in accordance with IEC 68-2-6
Torsion and bending load
Enclosure
MDS fixing
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Technical data for MDS D126
Serial number
Configuration memory
Application memory
read
write
)
g
Color
Material
Dimensions (D x H) in mm
Mounting hole (d in mm)
128 bytes
8 bytes (fixed code)
8 bytes
112 bytes
EEPROM
EEPROM 128 bytes gross
112 bytes net
When using the OTP area, 16 bytes of it must be
subtracted in 4-byte blocks
ISO 15693
10 years
approx. 2 ms/byte
approx. 10 ms/byte
Yes
Unlimited
min. 100,000
typ. 1,000,000
See Section Field data (Page 35)
≥ 25 mm (approx. 25 % reduction of the field data)
Inductive power transmission
(without battery)
IP68
1)
50 g
2)
20 g
2)
Not permissible
Black
Plastic PA 6.6 GF
50 (±0.3) x 3.6 (±0.2)
5,1 (±0,2)
M4 screws, tightening torque (at room
temperature) ≤ 1 Nm, adhesive
Transponder
7.4 MDS D126
169