Transponder
7.18 MDS D425
Write cycles at +40 °C, typical
Read/write distance (S
)
g
Distance from metal
Power supply
Degree of protection according to EN 60529
Shock, tested in accordance with IEC 68-2-27
Vibration, tested in accordance with IEC 68-2-6
Torsion and bending load
Housing
Color
Material
Dimensions (D x H)
MDS fixing
Ambient temperature
During operation
During transportation and storage
Weight
2 hours, 2 m, +20 °C
1)
steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75 °C
2)
The values for shock and vibration are maximum values and must not be applied continuously.
3)
Note
It is recommended that a test is performed in critical applications.
226
> 10
10
See section "Field data (Page 35)."
Can be mounted on metal
Inductive power transmission
(without battery)
IP68
1)
IPx9K
2)
50 g
3)
20 g
3)
not permitted
Black
Plastic PA 6.6 GF;
thread: Stainless steel
Wrench size 22 mm x 10 mm (±1) (without thread),
thread M6
Screws, tightening torque (at room temperature) ≤ 6 Nm
-25 °C ... +85 °C
-40 °C ... +125 °C
Approx. 35 g