7.7 MDS D160
MTBF (at +40 °C)
Bulk detection/multitag capability
Data retention
Read cycles
Write cycles at + 40 °C, typical
Write cycles, min.
Read/write distance (S
Distance from metal
Power supply
Degree of protection to EN 60529
Shock, tested in accordance with IEC 68-2-27
Vibration, tested in accordance with IEC 68-2-6
Torsion and bending load
Mechanical strength
Resistance to chemicals
MDS lifespan
Mechanical design
MDS fixing
Ambient temperature
Weight, approx.
1)
184
)
g
Isostatic pressure
Axial pressure
Radial pressure
Color
Material
Dimensions (D x H) in mm
During operation
Transport and
storage
No processing possible from +140 °C upwards
2 x 10
hours
6
Yes
10 years
Unlimited
1 000 000
100 000
See Chapter Field data (Page 35)
Min. 25 mm (approx. 30% reduction of the field
data)
Inductive power transmission
(without battery)
IP68 (24 hours, 2 m, +20 °C)
40 g
(18 ms; 6 axes; 2000 repeats/h)
10 g
(10 to 2000 Hz; 3 axes; 2.5 h)
Not permissible
300 bar for 5 min
1000 N for 10 s
1000 N for 10 s
All chemicals normally used in the washing
process
At least 100 wash cycles
White
PPS, pressed, impact-resistant plastic
16 (±0.2) x 3.0 (±0.2)
Patch, sew, glue
-25 °C to +85 °C
+125 °C
+175 °C
1)
+220 °C
1)
-25 °C to +100 °C
1 g
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Permanent
for 1000 hours
(20% reduction in the
limit distance)
500 x for 10 minutes
1 x for 30 seconds
SIMATIC RF200