Name
firmware_version
driver
driver_version
interface
baud
multitag_SLG
field_ON_time_SLG
status_ant
MDS_control
Note
Unassigned fields in the UDT are not listed here.
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Type
Possible values
word
0 to FF hex
0 to FF hex
char
31 hex
word
0 to FF hex
0 to FF hex
byte
01 hex
02 hex
byte
01 hex
03 hex
05 hex
byte
01 hex
byte
01 hex
byte
01 hex
02 hex
byte
00 hex
01 hex
10.2 Diagnostic functions
Comment
Firmware version: e.g. 3130 (=version 1.0)
= Version (high byte)
= Version (low byte)
Type of driver
3964R
Driver version: e.g. 3132 (=version 1.2)
= Version (high byte)
= Version (low byte)
Interface type
= RS-422
= RS-232
Baud rate
= 19.2 kBd
= 57.6 kBd
= 115.2 kBd
Number of transponders (multitag/bulk) that can
be processed in the antenna field
= Single tag mode
ISO transponder (non-specific)
Status of antenna
= Antenna is on
= antenna is off
Presence status
= Operation without presence message
= Operation with presence message
System diagnostics