Minimum Clearances - Siemens SIMATIC Ident System Manual

Hide thumbs Also See for SIMATIC Ident:
Table of Contents

Advertisement

RF200 system planning
4.2 Field data of transponders and readers
4.2.2

Minimum clearances

Minimum distance from transponder to transponder
The specified distances refer to a metal-free environment. For a metallic environment, the
specified minimum distances must be multiplied by a factor of 1.5.
Table 4- 13
MDS D100
MDS D117
MDS D124
MDS D126
MDS D127
MDS D139
MDS D160
MDS D165
MDS D200
MDS D261
MDS D324
MDS D339
MDS D400
MDS D421
MDS D422
MDS D423
MDS D424
MDS D425
MDS D426
MDS D428
MDS D460
MDS D521
MDS D522
MDS D522
Special variants
MDS D524
MDS D526
MDS D528
All values are in mm, relative to the operating distance (S
between transponder edge and transponder edge
44
Minimum clearances for transponders
RF210R
--
≥ 15
≥ 25
--
≥ 15
--
≥ 20
--
--
--
≥ 25
--
--
≥ 10
≥ 15
--
≥ 25
≥ 20
--
≥ 25
≥ 20
≥ 10
≥ 15
≥ 15
≥ 25
--
≥ 25
RF220R
RF240R
--
--
--
--
≥ 40
≥ 90
≥ 50
≥ 100
--
--
--
--
≥ 25
≥ 70
--
--
--
--
--
--
≥ 40
≥ 90
--
--
--
--
--
--
≥ 20
≥ 50
--
≥ 80
≥ 40
≥ 90
≥ 25
≥ 75
≥ 50
≥ 90
≥ 25
≥ 75
≥ 25
≥ 70
--
--
≥ 20
≥ 50
≥ 20
≥ 50
≥ 40
≥ 90
≥ 50
≥ 90
≥ 25
≥ 75
) between reader and transponder, and
a
System Manual, 07/2015, J31069-D0227-U001-A9-7618
RF260R
≥ 240
--
≥ 180
≥ 180
--
≥ 200
≥ 150
≥ 240
≥ 240
≥ 200
≥ 180
≥ 200
≥ 240
--
--
≥ 160
≥ 180
--
≥ 180
≥ 150
≥ 150
--
--
--
≥ 180
≥ 180
≥ 150
SIMATIC RF200

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic rf200

Table of Contents