Standards and Approvals
Climatic environmental conditions
The C230-2 may be used under the following climatic environmental conditions:
Environmental condi-
Temperature:
For horizontal installation:
For vertical installation:
Relative humidity
Air pressure
Contaminant concentra-
tion
Mechanical environmental conditions
The mechanical environmental conditions for the C230-2 are shown in the follow-
ing table in the form of sinusoidal oscillations.
Frequency range (Hz)
10 v f v 58
58 v f v 150
A-136
Areas of application
tions
From 0 to 55
From 0 to 40
From 5 to 95 %
From 1080 to 795 hPa
SO
: < 0.5 ppm;
2
Relative humidity < 60 %,
no moisture condensation
H
S: < 0.1 ppm;
2
Relative humidity < 60 %,
no moisture condensation
0.0375 mm amplitude
0.5 g constant acceleration
° C
° C
Without condensation, complies
with Relative Humidity (RH) load-
ing factor 2 in accordance with
IEC 1131-2
Corresponds to an altitude of
–1000 to 2000 m
Test:
10 ppm; 4 days
1 ppm; 4 days
Continuous
0.075 mm amplitude
1 g constant acceleration
E Siemens AG, 2003 All rights reserved
SIMOTION C230-2, 04.2003 Edition
Remarks
Occasional