en | Analog and Frequency Inputs
Channel is
linked to
ANA05
Available measurements for channel:
Measurement label
raw_name
raw_name_fi
name
name_fi
10.3.4

Configuring a multipoint adjustment

Example: Measurement of wheel force
1.
2.
3.
4.
5.
04.02.2019 | V 02 |
Physical property 'wheel force' not directly measureable
Load transfer through suspension kinematics
Physical value at sensor position defined by vehicle
Curve definition by online adjustment at vehicle
Click on 'Measurement Sources' in the Toolbox.
Expand the list of 'I/O Channels' by clicking on '+' in the DDU 7 Project Tree.
Drag the 'Multipoint Adjustment' analog signal source from the Toolbox and drop it on
the desired analog input channel in the DDU 7 Project Tree.
A 'Multipoint Adjustment Wizard' opens.
To activate the internal pullup-resistor, check the box.
The internal pullup-resistor is used to get a 5 V signal at the analog channel of the DDU 7.
It allows you to use a push-button.
The fixed value of the internal pullup-resistor is 3010 ohm. If using an additional external
pullup-resistor, set up the overall resistance.
Input pin
Pull-up
resistor is
activated
Function
mV value of sensor
filtered mV value of sensor
physical value of sensor
filtered physical value
Manual
Display Unit DDU 7
Characteristic
Adjustment
curve for
is disabled
sensor
Bosch Motorsport