Computed Sources; Configuring Computed Sources - Bosch DDU 7 Manual

Display unit
Table of Contents

Advertisement

Display Unit DDU 7
Notice!
Measurement of 'Revolution' is similar.
10.4

Computed sources

10.4.1

Configuring computed sources

Computed sources receive data from a measurement channel rather than an input pin.
Example: Sensitivity/offset calculation on input channel
1.
2.
3.
4.
Physical
limits of
channel
Bosch Motorsport
Sensitivity/Offset calculation on input channel
Characteristic curve calculation on input channel
Computed vehicle speed
PWM output control (covered in a special section)
Lap trigger (covered in a special section)
Click 'Measurement Sources' in the Toolbox.
Drag the 'Sensitivity/Offset' computed source from the Toolbox and drop it on
'Computed Channels' in the DDU 7 Project Tree.
A 'Computed Sensitivity/Offset Wizard' opens.
Click 'Next' when done.
The second part of the 'Computed Sensitivity/Offset Wizard' opens.
Manual
Analog and Frequency Inputs | en
Choose input
channel
Choose unit group
and unit of output
Enter sensitivity and offset
of conversion formula
Enter physical limits
of the channel
Choose data type of
the measurement
variable
Check the box to force
the channel's
quantization if the
quantization should be a
fixed value in the whole
CAN system
Enter name to
automatically create a new
measurement sheet
04.02.2019 | V 02 |
89