Counting Outing/Laps/Fragments - Bosch DDU 7 Manual

Display unit
Table of Contents

Advertisement

Display Unit DDU 7
14.2

Counting outing/laps/fragments

Functionality
The system is counting:
Outing:
Lap:
Fragment:
Channels for display
To display counters use the following channels:
Channel
Laptrigger_outcnt_dls
Laptrigger_lapctr_dls
Fractr
Counting in WinDarab
To automatically name recorded files use filename templates in WinDarab dialog:
Filename template
[outing]
[lap]
[fragment]
[###03] indicates: 'always use 3 digits with leading zeros'.
Bosch Motorsport
Power ON: system + measurement is initialized but not yet started
Global start condition fulfilled: recording starts
Reception of valid lap trigger: recording of lap completed, new lap starts
Power OFF or Global start condition not fulfilled: recording of lap completed, system
shutdown
The outing counter is incremented with each power cycle when at least one valid lap (not
by forced lap trigger) was recorded
Leaving the pits to lap trigger
Lap trigger to lap trigger
Enforced lap trigger (see Distance based forced trigger)
Test bench operation
Power cycle on track or box (e.g. engine stalled)
File fragmentation size [MB], time [sec]
Function
Outing counter
Lap counter
Fragment counter
Function
Value of outing counter
Value of lap counter
Value of fragment counter