MISCELLANEOUS WIRING INSTALLATION

Installing Attendant Console

Requirements
The attendant console is connected to an information outlet the same as any other voice
terminal. Figure 4-56 shows the connections required for the attendant console.
Power for two consoles only can be provided by the switch cabinet through an auxiliary
cable connected to the Trunk/Auxiliary Field. Whenever possible, power for the primary
attendant console should be provided by the switch cabinet. This makes the primary console
fully operational during short (less than 10 seconds) power outages.
Note: The attendant console cannot be powered from the switch cabinet on the System
75 XE.
Additional attendant consoles are remotely powered by the 346 bulk power supply or
individual power units. Refer to ADJUNCT POWERING for details on remote powering
from adjunct power units located at satellite locations, site locations, or information outlets.
Note: The 329A Power Unit should not be used to remotely power the attendant
console.
The maximum cabling distance for the attendant console powered from the switch cabinet is
350 feet (107 m). Maximum cabling distances for additional attendant consoles is 2400 feet
(732 m) for 24-gauge wire and 1500 feet (457 m) for 26-gauge wire.
Installation
1 .
Unpack attendant console and inspect for damage.
Determine port assignment of console from Attendant Console Form (see Note).
2 .
Note: The primary attendant console is always connected to control carrier
slot 02.
3 .
If power is to be supplied from the switch cabinet (not available on the System 75
XE), do steps 4 and omit step 5; otherwise, go to step 5.
4 .
Connect jumpers from the AUXILIARY connector ACC PWR terminals to the
attendant console appearance on the station side (see Figure 4-57).
If power is to be supplied at cross-connect field, connect power adapter cord
5 .
(Figure 4-6) to attendant console appearance on the station side and a power unit
located above the cross-connect field. If power is not supplied at cross-connect
field, provide power as described under ADJUNCT POWERING.
6 .
Install jumper wires at cross-connect field.
7 .
Connect console line jack on bottom of console to information outlet (Figure 4-56).
8 .
Install labels per Attendant Console Form and Display Module Form Assignments.
EXAMPLE:
Port Number
66-TYPE HARDWARE
A
02
01
Carrier
Slot
Circuit
4-87