Figure 2-118 Connections For Pdms In Data Mounting—Through Cable Access Panel - AT&T 75 Wiring Manual

Hide thumbs Also See for 75:
Table of Contents

Advertisement

6 . Administer per AT&T System 75 and System 75 XE Implementation and A T & T
System 75 and System 75 XE Administration.
Figure 2-118. Connections for PDMs in Data Mounting—Through Cable Access
Panel
Connection to Data Mounting Through Cross-Connect Field (Figure 2-119)
1 .
From Data Module Form, determine port assignment of PDMs:
2 .
Connect A25D cable to DCP-LINE connector on rear of data mounting.
3 .
Run and connect cable from data mounting to station side (see Note) of cross-
connect field.
Note: This connection is to a Z203A1 connecting unit provided in a Z100B1
connector module. If Z100A1 connector modules are used at the cross-connect
field, a connecting unit on the station side must be replaced with a Z203A1
connecting unit.
4 .
Install yellow auxiliary label on connector module.
5 .
Connect patch cords at cross-connect field (see Figure 2-119).
Administer per AT&T System 75 and System 75 XE Implementation and A T & T
6 .
System 75 and System 75 XE Administration.
EXAMPLE:
Port Number
Z100-TYPE HARDWARE
B
0 2
0 1
Carrier
Slot
Circuit
2-169

Advertisement

Table of Contents
loading

This manual is also suitable for:

75 xe

Table of Contents