Installing External Ringing - AT&T 75 Wiring Manual

Hide thumbs Also See for 75:
Table of Contents

Advertisement

Figure 3-112. Ground Start Key Installation

Installing External Ringing

Requirements
Figure 3-113 shows the connections for external ringing. External ringing is provided by a
device, such as a gong, chime, or bell, connected to an information outlet. The switch side of
the cross-connect field is connected to a TN742 or TN769 Analog Line circuit pack located in
a port carrier. The TN742 or TN769 circuit pack contains a maximum of eight ports.
The maximum number of devices that can be connected to one TN742 or TN769 circuit pack
port cannot exceed 3 ringer equivalences.
Installation
1 . Determine port assignment of Trunk Answer From Any Station (Call Answer
From Any Voice Terminal) feature from Console Parameters Form:
2.
Install patch cord or jumper wires at cross-connect field.
Mount ringing device at location specified on External Ringing Device Worksheet.
3.
Run 2-pair line cord (modular plug at one end) from information outlet to ringing
4.
device (see Figure 3-113).
5.
Connect red (R) and green (T) leads to ringing device.
Administer per AT&T System 75 and System 75 XE Implementation and A T & T
6.
System 75 and System 75 XE Administration.
EXAMPLE:
Port Number
110-TYPE HARDWARE
B
02
01
Carrier
Slot
Circuit
3-151

Advertisement

Table of Contents
loading

This manual is also suitable for:

75 xe

Table of Contents