Calling Up Coding Level 2; General - Viessmann FB2B Installation And Service Instructions Manual

4.8 to 26 kw gas condensing/solar storage combi boiler natural gas and lpg version gas council no.: 47-819-18 19 kw 47-819-19 26 kw
Table of Contents

Advertisement

Code 2

Calling up coding level 2

Note
■ In coding level 2, all codes are acces-
sible, including the codes from coding
level 1.
■ Codes that have no function due to the
heating system equipment level or the
setting of other codes are not dis-
played.
■ Heating systems with one heating cir-
cuit without mixer and one or two heat-
ing circuits with mixer:
The heating circuit without mixer is
designated "Heating circuit 1" and
the heating circuits with mixer as
"Heating circuit 2" or "Heating cir-
cuit 3".
If the heating circuits were given indi-
vidual designations, the selected des-
ignation and "HC1", "HC2" or "HC3"
appear instead.
1. Press OK and å simultaneously
for approx. 4 s.
2. Press OK and ä simultaneously for
approx. 4 s.
3. "Coding level 2"

General

Coding
Coding in the delivered condition
00:2
System version 1:
One heating circuit with-
out mixer (A1), with DHW
heating
76
4. Select group of required coding
address:
■ "General"
■ "Boiler"
■ "DHW"
■ "Solar"
■ "Heating circuit 1/2/3"
■ "All cod. or solar"
In this group, all coding addresses
(except the coding addresses from
the "Solar" group) are displayed in
ascending order.
5. Select coding address.
6. Select value according to the follow-
ing tables and confirm with "OK".
7. If you want to reset all codes to
their delivered condition:
Select "Standard setting" in "Cod-
ing level 2".
Note
This also resets codes from coding
level 1.
Possible change
00:2
For system schemes, see
to
the following table:
00:10

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vitodens 242-f

Table of Contents