Select Boiler - Viessmann FB2B Installation And Service Instructions Manual

4.8 to 26 kw gas condensing/solar storage combi boiler natural gas and lpg version gas council no.: 47-819-18 19 kw 47-819-19 26 kw
Table of Contents

Advertisement

General
(cont.)
Coding in the delivered condition
Set flow temperature in case of ext. Demand
9b:70
Set flow temperature for
external demand 70 °C

Select boiler

Coding
Coding in the delivered condition
Burner service in 100 hours
21:0
No service interval (hours
run) selected
Service interval in months
23:0
No time interval for
burner service
Service status
24:0
No "Service" display
Filling/Venting
2F:0
Venting program/fill pro-
gram disabled
Possible change
9b:0
Set flow temperature for
to
external demand adjusta-
9b:127
ble from 0 to 127 °C (limited
by boiler-specific parame-
ters)
Possible change
21:1
The number of hours run
to
before the burner should
21:100
be serviced is adjustable
from 100 to 10,000 h
One adjusting step ≙
100 h
23:1
Interval adjustable from 1
to
to 24 months
23:24
24:1
"Service" display (the
address is automatically
set and must be manually
reset after a service has
been carried out)
2F:1
Venting program enabled
2F:2
Fill program enabled
Code 1