Viessmann FB2B Installation And Service Instructions Manual page 17

4.8 to 26 kw gas condensing/solar storage combi boiler natural gas and lpg version gas council no.: 47-819-18 19 kw 47-819-19 26 kw
Table of Contents

Advertisement

Electrical connections
?
A
aVG
%
X4
7654
X3
A Solar control module KM BUS con-
nection (connected in the delivered
condition)
B Power supply, solar control module
(connected in the delivered condi-
tion)
Plug 230 V~
sA Cylinder primary pump D (fitted
and connected)
(cont.)
!
B
N L
?
230V~
321
100
35
20
96
C External safety solenoid valve
D Cylinder primary pump
fÖ Power supply
Installation sequence
C
M
D
1~
L N
N
L
N
L
L1
?
?
?
230V~
40
53
21
(LPG)
■ Remove any existing individual
cores.
Danger
Incorrect core termination
can cause severe injuries
and damage to the equip-
ment.
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vitodens 242-f

Table of Contents