Viessmann FB2B Installation And Service Instructions Manual page 113

4.8 to 26 kw gas condensing/solar storage combi boiler natural gas and lpg version gas council no.: 47-819-18 19 kw 47-819-19 26 kw
Table of Contents

Advertisement

Fault codes
(cont.)
Displayed
System characteris-
fault code
tics
Fd
Burner in a fault
state
FE
Burner blocked or in a
fault state
FF
Burner blocked or in a
fault state
Cause
Measures
Fault, burner con-
Check ignition electrodes
trol unit
and connecting cables.
Check whether a strong
interference (EMC) field
exists near the appliance.
Press reset button R.
Replace control unit if the
fault persists.
Boiler coding card
Press reset button R.
or main PCB faulty
Replace boiler coding
card or control unit if the
fault persists.
Internal fault or
Start the appliance again.
reset button R
Replace the control unit if
blocked
the appliance will not
restart.
Troubleshooting
113