Viessmann FB2B Installation And Service Instructions Manual page 87

4.8 to 26 kw gas condensing/solar storage combi boiler natural gas and lpg version gas council no.: 47-819-18 19 kw 47-819-19 26 kw
Table of Contents

Advertisement

DHW
(cont.)
Coding in the delivered condition
67:40
For solar DHW heating:
set DHW temperature
40 °C. DHW reheating is
suppressed above the
selected set temperature
(DHW heating blocked by
the boiler).
6C:100
Set speed; internal circu-
lation pump with DHW
heating 100 %
6F:...
Maximum output for
DHW heating in %, speci-
fied by the boiler coding
card
71:0
DHW circulation pump:
"ON" according to time
program
72:0
DHW circulation pump:
"ON" according to time
program
73:0
DHW circulation pump:
"ON" according to time
program
Possible change
67:0
Set DHW temperature
to
adjustable from 0 to 95 °C
67:95
(limited by boiler-specific
parameters)
6C:0
Set speed adjustable from
to
0 to 100 %
6C:100
6F:0
Max. output for DHW heat-
to
ing adjustable from min.
6F:100
output to 100 %
71:1
"OFF" during DHW heating
to the first set value
71:2
"ON" during DHW heating
to the first set value
72:1
"OFF" during DHW heating
to the second set value
72:2
"ON" during DHW heating
to the second set value
73:1
"ON" from once per hour
to
for 5 min up to 6 times per
73:6
hour for 5 min during the
time program
73:7
Constantly "ON"
Code 2
87