2.1 Quick Start
© CalAmp
2.2 Programming Option 2 - Text User Interface

2.2.1 Requirements

To program your Phantom II using the text interface, you will need:
At least (2) two Phantom II (factory configured) with Power
Adapter and Rubber Ducky Antenna. Each factory configured
Phantom II has the following default settings: 'Remote' with Local
Network Settings 'Static' (IP Address 192.168.1.254, Subnet
Mask 255.255.255.0, Gateway 192.168.1.1)
PC with NIC (Ethernet) card and COM (serial) port with
HyperTerminal (or equivalent). If your PC does not have a Serial
port, you will need a serial to USB adapter
Diagnostic serial cable (DB9-DB9)
Ethernet cable. If your PC does not support Auto MDIX, you will
need to use a crossover cable

2.2.2. Device Connections

Connect Rubber Ducky to the antenna port of each Phantom II
Connect power adapters to 120 VAC outlets and to each
Phantom II
Using a diagnostic serial cable, connect the DIAGNOSTICS port
of the Phantom II that will be the MASTER device to an available
COM port on the PC

2.2.3 Serial Configuration

Run HyperTerminal (or equivalent terminal program) on the PC
and configure the selected Serial/COM port for 115200 bps, 8
data bits, no parity, 1 stop bit, and no flow control
Activate the HyperTerminal connection. Press [Enter]. A login
prompt will appear
Enter default user name (admin). Press [Enter]
Enter default password (admin). Press [Enter]
Phantom II
16