Master Configuration; Remote Configuration; Check Connectivity - Cal Amp Phantom II Operating Manual

Wireless ethernet bridge/serial gateway
Table of Contents

Advertisement

2.1 Quick Start
© CalAmp

2.1.4 Master Configuration

Select Network Configuration > Local IP Config. Assign unit IP
Address, Subnet Mask and Gateway. [Submit]
NOTE: If the Local IP Address of the Phantom II is changed to a new
network, the PC NIC IP Address must also be reassigned to the new
network.
Open a Web Browser and enter the newly assigned IP Address
of the Phantom II into the URL address line
A login window will appear. Enter admin for the default user-
name. Enter admin for the default password.
Press [Enter]
Select Radio Configuration
Select Master as the Operation Mode
Select Point-to-Point as the Network Type. [Submit]

2.1.5 Remote Configuration

Repeat the above for the other Phantom II, giving it a new unique
IP Address. By default the Operation Mode is already configured
as a Remote
Change the Destination Unit on the Master radio to match the
Unit Address of the Remote radio. [Submit]

2.1.6 Check Connectivity

With both units powered-on, in proximity to each other, their
RSSI LEDs should be illuminated
With the PC connected to one of the Phantom II units with an
Ethernet cable, open a web browser and enter the IP Address of
'the other' unit to verify a wireless connection
To simulate data traffic over the radio network, connect a PC to
the Ethernet port of the Phantom II and PING each unit in the
network multiple times
Phantom II
.
15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents