Omron G9SP-N20S Network Connection Manual page 26

Safety controller
Hide thumbs Also See for G9SP-N20S:
Table of Contents

Advertisement

4
The Watch Tab Page is displayed in
the lower section of the Edit Pane.
5
Confirm that the following values
are displayed in the Name Columns.
Input_Start
Output_Status
Output_ErrorCode1
Output_ErrorCode2
G9SP_ResponseData[0-198]
G9SP_CommandData
*If the necessary variables are not
displayed, click Input Name to
add.
6
Click TRUE on the Modify Column
of Input_Start.
The Online value of Input_Start
changes to True.
The Online Values of Output Status
and etc. are initialized to FFFF.
When serial communications are
completed normally, the Online
Values of Output Status and etc.
change to 0000.
7
The response data that was
received are stored in
G9SP_ResponseData[0] to [198].
Specify variables you want to see in
the Watch Tab Page as shown in the
right figure and check them.
If values are stored in
G9SP_ResponseData[2] to [5] as
shown on the right, the operation is
completed normally.
G9SP_ResponseData[2]:C3
G9SP_ResponseData[3]:00
G9SP_ResponseData[4]:00
G9SP_ResponseData[5]:CB
7. Connection Procedure
←Response length
←End code (H)
←End code (L)
←Service code
←Communications
send data
←Same as above
←Same as above
←Same as above
23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nj seriesG9sp series