6.2.1 Matching the unit to the connection voltage

DANGER
NOTICE
Due to special electronic components, the unit generates a small fault
current. To ensure that the residual current device does not trip during
normal operation, each unit must have its own residual current device.
Potential equalisation
Image: Symbol for potential equalisation
The unit can be included in a potential equalisation system by means of
appropriately sized wiring.
Risk of personal injury and physical damage from electric shock
• Before working on the FlexiFusion Team, ensure that both power circuits
within the unit are not live.
• Do not operate the unit with the housing open.
Risk of property damage from incorrect connection voltage
• Before making the connection, measure the connection voltage and check
the set voltage on the transformers in the unit.
When the unit is delivered, it is preset to a certain connection voltage or
voltage range.
If the connection voltage on site differs from the preset connection
voltage, damage to the unit can arise.
Before connecting the unit, the connection voltage must be measured
and the transformers in the unit checked, and if necessary they must be
reconnected.
Installation instructions
Connecting the unit
23