PARTS
When servicing plumbing components, take care not to damage the threads of each individual item. Damaged threads can cause leaks and loss of
pressure, which could adversely affect the performance of the dishmachine. It is strongly recommended that thread tape—used in conservative amounts—
be applied to threads when joining components together. Do not use thread-sealing compounds, sometimes referred to as "pipe dope." Compounds can
be ejected from the threads during the tightening process and become lodged in key components, rendering them useless, including solenoid valves and
pressure gauge ball valves.
ITEM
QTY
1
1
2
1
3
2
4
1
5
1
07610-003-61-42-U
1
5
DESCRIPTION
Complete Assembly
Union, 3/4'' NPT, Black Iron
Bushing, Reducing, 3/4'' to 1/2''
Elbow, 3/4" 90° Street
Nipple, Close, 3/4'' NPT, Black Iron
Steam Trap, 3/4" NPT

STEAM INLET PLUMBING

TempStar S
4
NOTICE
2
3
PART NUMBER
05700-002-01-55
04730-912-01-00
04730-911-02-34
04730-011-87-37
04730-907-01-00
06680-500-02-77
45