INSTALLATION
ELECTRICAL POWER
CONNECTIONS
Disconnect electrical
power supplies
and tag out in
accordance with
appropriate procedures/
codes at the
disconnect switch.
!
CAUTION
VOLTAGE CHECK
!
CAUTION
i
07610-003-61-42-U
Electrical and grounding connections must comply with the applicable portions of the
National Electrical Code ANSI/NFPA 70 (latest edition) and/or other electrical codes.
Disconnect electrical power supply and place a tag at the disconnect switch to indicate
that you are working on the circuit.
The dishmachine data plate is located on the right side and to the front of the machine.
Refer to the data plate for machine operating requirements, machine voltage, total
amperage load, and serial number.
1. Open the control box. This will require taking a phillips screwdriver and removing
the four screws on the front cover of the control box.
2. Install 3/4" conduit into the pre-punched holes in the back of the control box.
3. Route power wires and connect to power block and grounding lug.
4. Install the service wires (L3 for 3-Phase only) to the appropriate terminals as they
are marked on the terminal block.
5. Install the grounding wire into the lug provided.
6. Tighten the connections.
NOTE: It is recommended that "DE-OX" or similar anti-oxidation agent be
NOTICE
used on all power connections.
CAUTION: Improperly connecting external devices can cause damage to the
machine and/or electrical infrastructure! See Addendum for a wiring guide.
1. Ensure that the power switch is in the OFF position and apply power to the
dishmachine.
2. Check the incoming power at the terminal block and ensure it corresponds to
the voltage listed on the data plate. If not, contact a qualified service agency to
examine the problem.
CAUTION: Do not run the dishmachine if the voltage is too high or too low (refer to
applicable electrical codes).
3. Shut the service breaker off and mark it as being for the dishmachine.
4. Advise all proper personnel of any problems and of the location of the service
breaker. Replace the control box cover and tighten-down the screws.
INSTRUCTIONS
Ground
NOTICE
Imbalanced
wild leg goes
to L3.
10